Mitsubishi Electric 800 Series Instruction Manual page 69

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

• Output frequency, output current and output voltage for past eight alarms at the inverter alarm occurrence can be read.
PNU
Latest fault monitor frequency, current,
P949.1 to P949.8
and voltage
Frequency, current, and voltage
P949.9 to P949.16
monitored when the second latest fault
occurs
Frequency, current, and voltage
P949.17 to P949.24
monitored when the third latest fault
occurs
Frequency, current, and voltage
P949.25 to P949.32
monitored when the fourth latest fault
occurs
Frequency, current, and voltage
P949.33 to P949.40
monitored when the fifth latest fault
occurs
Frequency, current, and voltage
P949.41 to P949.48
monitored when the sixth latest fault
occurs
68
PPO TYPE SUPPORT SPECIFICATION
Item
P949.1
P949.2
P949.3
P949.4 to P949.8
P949.9
P949.10
P949.11
P949.12 to P949.16
P949.17
P949.18
P949.19
P949.20 to P949.24
P949.25
P949.26
P949.27
P949.28 to P949.32
P949.33
P949.34
P949.35
P949.36 to P949.40
P949.41
P949.42
P949.43
P949.44 to P949.48
Data definition
Output frequency
Output current
Output voltage
All 0
Output frequency
Output current
Output voltage
All 0
Output frequency
Output current
Output voltage
All 0
Output frequency
Output current
Output voltage
All 0
Output frequency
Output current
Output voltage
All 0
Output frequency
Output current
Output voltage
All 0
Data type
AUs16
AUs16
AUs16
AUs16
AUs16
AUs16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a8np

Table of Contents