Mitsubishi Electric 800 Series Instruction Manual page 58

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Name
SU signal
OL signal
IPF signal
ESW
(Standard format)
Terminal RUN function
Command count
SU signal
OL signal
IPF signal
Terminal RUN function
Alarm 1
Alarm 2
*1
ESW
(Extended format)
Alarm 3
Alarm 4
Alarm 5
Alarm 6
Alarm 7
Command count
Bit
0
0: OFF, 1: ON (up to frequency)
1
0: OFF, 1: ON (overload alarm)
2
0: OFF, 1: ON (an instantaneous power failure or undervoltage occurs)
*7
3
Inverter running
4 to 7
Not used (0 is set)
8 to 15
Echo back of the command request.
0
0: OFF, 1: ON (up to frequency)
1
0: OFF, 1: ON (overload alarm)
2
0: OFF, 1: ON (an instantaneous power failure or undervoltage occurs)
*7
3
Inverter running
4
Not used (0 is set)
0: REF1 command execution normal, 1: REF1 command execution error (outside
5
setting range)
0: REF2 command execution normal, 1: REF2 command execution error (outside
6
setting range)
0: REF3 command execution normal, 1: REF3 command execution error (outside
7
setting range)
0: REF4 command execution normal, 1: REF4 command execution error (outside
8
setting range)
0: REF5 command execution normal, 1: REF5 command execution error (outside
9
setting range)
0: REF6 command execution normal, 1: REF6 command execution error (outside
10
setting range)
0: REF7 command execution normal, 1: REF7 command execution error (outside
11
setting range)
12 to 15
Echo back of the command request.
Definition
The function assigned to terminal RUN
is activated.
The function assigned to terminal RUN
is activated.
PPO TYPE SUPPORT SPECIFICATION
7
57