Mitsubishi Electric 800 Series Instruction Manual page 59

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Name
Monitor item assignment
to STS1 to STS7
REF1 to REF7
(when AK = "15")
Command assignment
to REF1 to REF7
Monitor item assignment
to STS1 to STS7
STS1 to STS7
(when AK = "15")
Command assignment
to REF1 to REF7
REF1 to REF7
Command value of
(when AK  "15")
REF1 to REF7
STS1 to STS7
Monitor value of STS1 to
(when AK  "15")
STS7
*1
Valid only for the FR-A800 series when Pr.1110 PROFIBUS format selection = "1, 11" (extended format). (Refer to
*2
PZD enable and command count request can be executed.
*3
If it takes time to perform slave side processing, slave side busy status is announced since reply to the master will be delayed. During
busy status, other response data are unfixed values. When the slave side is busy, request from the master is invalid. Therefore, the same
request must be sent again. The response data of the FR-A8NP during Busy status is as follows.
ID
During busy status and inverter reset
PKW
0
ZSW Bit 15 (BUSY) = "1"
PZD
Other error Bit = "0"
*4
When a value other than 9999 is set in Pr.430 Pulse monitor selection under position control (Pr.800 = "3, 4") for the FR-A800 series,
pulse monitor is selected. (Refer to the Instruction Manual (Detailed) of the inverter for pulse monitor.)
*5
Signal names are initial values. Using Pr.180 to Pr.186, you can change output signal functions. Refer to the Instruction Manual
(Detailed) of the inverter for details of Pr.180 to Pr.186.
*6
For the FR-F800 series, no function is assigned in the initial setting.
*7
These signals are set in the initial setting. Using Pr.190, output signal assigned to the device number can be changed.
For details on Pr.190, refer to the Instruction Manual (Detailed) of the inverter.
58
PPO TYPE SUPPORT SPECIFICATION
Bit
Function number of the monitor item assigned to STS1 to STS7 (Refer to
0 to 7
65.)
8 to 15
Function number of the command assigned to REF1 to REF7 (Refer to
0 to 7
Echo back value of Bits 0 to 7 (STS monitor item assignment) of REF1 to REF7
8 to 15
Echo back value of Bits 8 to 15 (REF command assignment) of REF1 to REF7
Command value of the function assigned to Bits 8 to 15 (REF command
0 to 15
assignment) of REF1 to REF7 when AK = '"15"
Monitor value of the item assigned to Bits 0 to 7 (STS monitor item assignment) of
0 to 15
REF1 to REF7 when AK = "15"
During busy status and other than inverter rest
All 0 when AK = "0"
Reply data when AB  "0"
ZSW Bit 15 (BUSY) = "1"
Other error Bit = inverter status data
Definition
page
page
page