• Inverters supporting the Pr.1110 PROFIBUS format selection setting value "11"
Model
FR-A820-00046(0.4K) to 04750(90K)
FR-A840-00023(0.4K) to 06830(280K)
FR-A842-07700(315K) to 12120(500K)
FR-A846-00023(0.4K) to 03610(132K)
NOTE
• As shown in the following table, the availability of communication methods and function depends on a SERIAL number
combination of the applied inverter and FR-A8NP. Check the circuit board of the FR-A8NP for its SERIAL number.
• Availability of communication methods
For the inverter manufactured in Japan
SERIAL number of
the FR-A8NP
82 or earlier
Pr.1110 = "0, 1" valid.
83 or later
For the inverter manufactured in China
SERIAL number of
the FR-A8NP
82 or earlier
Pr.1110 = "0, 1" valid.
83 or later
Country of origin indication
MADE in Japan
MADE in China
SERIAL number of the FR-A800 series inverter
7X or earlier
SERIAL number of the FR-A800 series inverter
7Y or earlier
SERIAL number
7Y or later
7Z or later
7Y or later
Pr.1110 = "0, 1" valid.
Setting Pr.1110 = "11" is the same as setting
Pr.1110 = "1".
Pr.1110 = "0, 1 or 11" valid.
7Z or later
Pr.1110 = "0, 1" valid.
Setting Pr.1110 = "11" is the same as setting
Pr.1110 = "1".
Pr.1110 = "0, 1 or 11" valid.