Mitsubishi Electric 800 Series Instruction Manual page 28

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Pr.340
Pr.79
Operation mode at power-ON, at power
setting
setting
0
NET operation mode
1
PU operation mode
2
NET operation mode
*2
10, 12
3, 4
External/PU combined operation mode
*4
NET operation mode
6
7
External operation mode
*1
Operation mode cannot be directly changed between the PU operation mode and Network operation mode.
*2
The Pr.340 settings "2 or 12" are mainly used for communication operation using the inverter RS-485 terminal. When a value other than
"9999" (selection of automatic restart after instantaneous power failure) is set in Pr.57 Restart coasting time, the inverter will resume the
same operation state which was in before after power has been restored from an instantaneous power failure. When Pr.340 = "1 or 10", a
start command turns off if power failure has occurred and then restored during a start command is on.
*3
Switching between the PU and NET operation modes is available with the key on the operation panel or the X65 signal.
*4
When Pr.128 = "50, 51, 60, or 61", the same operation mode as when Pr.79 = "0" is selected.
*5
Refer to
page
62,
restoration, or after a reset
page 88
for a switching method from the network.
Operation mode switchover
Switching between the PU and NET operation mode is
*3*5
enabled.
Same as when Pr.340 = "0"
NET operation mode fixed
Same as when Pr.340 = "0"
Switching between the PU and NET operation mode is
*3*5
enabled while running.
Same as when Pr.340 = "0"
INVERTER SETTING
4
27