Wiring The Power Inputs - Planet IGS-4215-16T2S User Manual

Industrial l2/l4 16-port 10/100/1000t+2-port 100/1000x sfp managed switch
Hide thumbs Also See for IGS-4215-16T2S:
Table of Contents

Advertisement

2.1.5 Wiring the Power Inputs

The 6-contact terminal block connector on the top panel of Industrial Ethernet Switch is used for two redundant power inputs.
Please follow the steps below to insert the power wire.
When performing any of the procedures like inserting the wires or tightening the
wire-clamp screws, make sure the power is OFF to prevent from getting an electric
shock.
1.
Insert positive/negative DC power wires into Contacts 1 and 2 for Power 1, or 5 and 6 for power.
2.
Tighten the wire-clamp screws for preventing the wires from loosening.
1.
2.
3.
1
2
3
Power 1
+
-
The wire gauge for the terminal block should be in the range between 12 and 24
AWG.
The power input range is DC 12V ~ 48V and supports AC 24V.
Use one power input when using AC 24V.
4
5
6
Fault
Power 2
+
-
28
User's Manual of IGS-4215-16T2S

Advertisement

Table of Contents
loading

Table of Contents