Industrial L3 Multi-Gigabit/10Gigabit
Managed Ethernet Switch
IGS-6325-4T2X/IGS-6325-4UP2X/IGS-6325-5X1T
Quick Installation Guide

Advertisement

Table of Contents
loading

Summary of Contents for Planet IGS-6325-4UP2X

  • Page 1 Industrial L3 Multi-Gigabit/10Gigabit Managed Ethernet Switch IGS-6325-4T2X/IGS-6325-4UP2X/IGS-6325-5X1T Quick Installation Guide...
  • Page 2: Table Of Contents

    Table of Contents 1. Package Contents ................. 3 2. Requirements ..................4 3. Wiring the Power Inputs ............... 5 3.1 Grounding the Device ..............7 4. Terminal Setup ..................8 4.1 Logging on to the Console .............. 9 4.2 Configuring IP Address via Console ..........10 4.3 Storing the current switch configuration .........
  • Page 3: Package Contents

    1. Package Contents Thank you for purchasing PLANET L3 Multi-Gigabit/10Gigabit Industrial Managed Switch, IGS-6325-4T2X/IGS-6325-4UP2X/IGS-6325-5X1T. “Industrial Managed Switch” mentioned in this Quick Installation Guide refers to the above models. The descriptions of these models are shown below: Industrial L3 4-Port 2.5GBASE-T + 2-Port 10G SFP+ IGS-6325-4T2X Managed Ethernet Switch Industrial L3 4-Port 2.5GBASE-T 802.3bt PoE + 2-Port...
  • Page 4: Requirements

    2. Requirements Industrial Managed Switch provides remote login interface management purposes. The following equipment is necessary for further management:  Workstations running Windows XP/2003/2008/Vista/7/8/10/11, MAC OS X or later, Linux, UNIX, or other platforms are compatible with TCP/IP Proto- cols.  Workstations are installed with Ethernet NIC (Network Interface Card).
  • Page 5: Wiring The Power Inputs

    3. Wiring the Power Inputs The Upper Panel of the Industrial Managed Switch indicates an inlet power socket and consists of one green terminal block connector with 6 contacts. Please follow the steps below to insert the power wire. 1. Insert positive/negative DC power wires into Contacts 1 and 2 for Power 1, or Contacts 5 and 6 for Power 2.
  • Page 6 1 2 3 4 5 6 DC Input: 48-54V , 8.3A max. PWR1 Alarm PWR2 Figure 3-2: IGS-6325-4UP2X Upper Panel IGS-6325-4UP2X DC Input Voltage 48-54VDC Max. DC Input Current 8.3A PWR1 and PWR2 must provide exactly the same DC voltage for power load balance while operating with dual power input.
  • Page 7: Grounding The Device

    1. The wire gauge for the terminal block should be in the range from 12 to 24 AWG. 2. Please check the AWG Ampere specification before connecting PLANET Industrial Managed Switch. 3.1 Grounding the Device Users MUST complete grounding wired with the device; otherwise, a sudden lightning could cause fatal damage to the device.
  • Page 8: Terminal Setup

    4. Terminal Setup To configure the system, connect a serial cable to a COM port on a PC or notebook computer and to RJ45 type serial (console) port of the Industrial Managed Switch. IGS Industrial Managed Switch PC/Workstation with Terminal Emulation Software RJ45 to DB9 RS232 Cable Console 115200,N,8,1...
  • Page 9: Logging On To The Console

    4.1 Logging on to the Console Once the terminal has been connected to the device, power on the Industrial Managed Switch and the terminal will display “running testing procedures”. Then, the following message asks to log in user name and password. The factory default user name and password are shown as follows as the login screen in Figure 4-1 appears.
  • Page 10: Configuring Ip Address Via Console

    4.2 Configuring IP Address via Console The Industrial Managed Switch is shipped with default IP address shown below: IP Address: 192.168.0.100 Subnet Mask: 255.255.255.0 To check the current IP address or assign a new IP address to the Switch, please use the commands as follows  Display of the Current IP Address 1. At the “#”...
  • Page 11: Storing The Current Switch Configuration

    IP Address: 192.168.1.100 Subnet Mask: 255.255.255.0 Figure 4-3: Configuring IP Address Screen 4. Enter “exit” command twice to return to the global configuration mode. 5. Repeat step 1 to check if the IP address has changed. 4.3 Storing the current switch configuration 1. At the “#” prompt, enter the following command and press <Enter>. # copy running-config startup-config Figure 4-4: Saving Current Configuration Command Screen If the IP is successfully configured, the Industrial Managed Switch will apply the new IP address setting immediately. You can access the Web interface of the Industrial Managed Switch through the new IP address.
  • Page 12: Starting Web Management

    5. Starting Web Management The following shows how to start up the Web Management of the Industrial Managed Switch. Note the Industrial Managed Switch is configured through an Ethernet connection. Please make sure the manager PC must be set to the same IP subnet address.
  • Page 13 2. When the following dialog box appears, please enter the default user name “admin” and password “admin” (or the password you have changed before) as shown in Figure 5-2. Default IP Address: 192.168.0.100 Default Username: admin Default Password: admin Figure 5-2: Login Screen 3. After entering the password, the main screen appears as shown in Figure 5-3.
  • Page 14 Menu always contains one or more buttons, such as “System”, “Switching”, “Routing”, “QoS”, “Security”, “Ring” and “Maintenance”. Figure 5-4: Switch Menu Figure 5-5: Switch Sub-menu Figure 5-6: Switch Sub-menu In addition to the menu items that IGS-6325-4T2X/IGS-6325-5X1T presents above, the IGS-6325-4UP2X which supports IEEE 802.3bt PoE also provides a specific menu item for related PoE functional settings.
  • Page 15: Saving Configuration Via Web

    Figure 5-6: Switch Sub-menu (ONLY for IGS-6325-4UP2X) Now, you can use the Web management interface to continue the Switch management. If you are not familiar with Switch functions or the related para- meter, press “Help icon” anytime on the Web page to get the help description. 5.2 Saving Configuration via Web To save the current configuration as a startup configuration, click the “Save”...
  • Page 16 3. Or the other way to save the setting is to Click Maintenance, and Save Startup Config.
  • Page 17: Restoring Default Configuration

    6. Restoring Default Configuration  IP address has been changed or admin password has been forgotten – To reset the IP address to the default IP address “192.168.0.100” and the user password to factory default (default password is admin), press the recessed reset button on the front panel for about 10 seconds. After the device reboots, you can log in the management Web interface within the same subnet of 192.168.0.xxx with default password.
  • Page 18 1G/2.5G LNK/ACT LNK/ACT IGS-6325-4T2X Figure 6-2: IGS-6325-4T2X Reset Button P2 Alarm Ring R.O. Usage 120W 240W 360W 2.5GBASE-T Console 115200,N,8,1 Reset Button Reset 1G/2.5G LNK/ACT 10/100 LNK/ACT 802.3bt PoE++ 802.3at PoE+ 1G/2.5G LNK/ACT LNK/ACT IGS-6325-4UP2X Figure 6-3: IGS-6325-4UP2X Reset Button...
  • Page 19: Customer Support

    7. Customer Support Thank you for purchasing PLANET products. You can browse our online FAQ resource on PLANET web site to check if it could solve your issue. If you need more support information, please contact PLANET switch support team. PLANET online FAQs: https://www.planet.com.tw/en/support/faq Switch support team mail address: support@planet.com.tw Industrial User’s Manual: https://www.planet.com.tw/en/support/downloads?&method=keyword&keyword...