• Sample Interval
• Sample Type
• Rising Threshold
• Falling Threshold
• Rising Event
• Falling Event
• Owner
Buttons
: Click to apply changes.
Pkts158to255Octets: The total number of frames (including bad packets)
received and transmitted where the number of octets falls within the
specified range (excluding framing bits but including FCS octets).
Pkts256to511Octets: The total number of frames (including bad packets)
received and transmitted where the number of octets falls within the
specified range (excluding framing bits but including FCS octets).
Pkts512to1023Octets: The total number of frames (including bad packets)
received and transmitted where the number of octets falls within the
specified range (excluding framing bits but including FCS octets).
Pkts1024to1518Octets: The total number of frames (including bad packets)
received and transmitted where the number of octets falls within the
specified range (excluding framing bits but including FCS octets).
Sample interval (1–2147483647)
The method of sampling the selected variable and calculating the value to be
compared against the thresholds, possible sample types are:
Absolute: Get the sample directly (default).
Delta: Calculate the difference between samples.
Rising threshold value (0–2147483647)
Falling threshold value (0–2147483647)
Event to fire when the rising threshold is crossed
Event to fire when the falling threshold is crossed
Specify an owner for the alarm
Figure 4-2-44: RMON Alarm Status Page Screenshot