Summary of Contents for Planet IGS-5225-4T2S

  • Page 1 Industrial L2+ Multi-Port Full Gigabit Managed Ethernet Switch IGS-5225-4T2S/IGS-5225-4UP1T2S IGS-5225-8P2S/IGS-5225-8P4S/IGS-5225-8P2T2S Quick Installation Guide...
  • Page 2: Table Of Contents

    Table of Contents 1. Package Contents ..............3 2. Requirements ................5 3. Wiring the Power Inputs ............6 4. Terminal Setup ................8 5. Logging on to the Console ............9 6. Configuring IP address ..............11 7. Starting Web Management ............14 8. Saving Configuration via Web ............17 9.
  • Page 3: Package Contents

    1. Package Contents Thank you for purchasing PLANET L2+ Industrial Managed Switch, IGS-5225 Series. The descriptions of these models are as follows: Industrial L2+ 4-Port 10/100/1000T + 2-Port IGS-5225-4T2S: 100/1000X SFP Managed Switch Industrial L2+ 4-Port 10/100/1000T Ultra PoE + IGS-5225-4UP1T2S: 1-Port 10/100/1000T + 2-Port 100/1000X SFP Managed Switch Industrial L2+ 8-Port 10/100/1000T 802.3at IGS-5225-8P2S: PoE + 2-Port 100/1000X SFP Managed Ethernet Switch Industrial L2+ 8-Port 10/100/1000T 802.3at IGS-5225-8P4S: PoE + 4-Port 100/1000X SFP Managed Ethernet Switch Industrial L2+ 8-Port 10/100/1000T 802.3at IGS-5225-8P2T2S: PoE + 2-Port 10/100/1000T + 2-Port 100/1000X SFP Managed Ethernet Switch “Industrial Managed Switch” mentioned in this Quick Installation...
  • Page 4 Wall Mounting Kit x 1 z DB9 to RJ45 Interface RS232 Console Cable x 1 z Dust Cap (Please refer to the table below.) RJ45 Dust Cap SFP Dust Cap IGS-5225-4T2S IGS-5225-8P2S IGS-5225-8P4S IGS-5225-8P2T2S IGS-5225-4UP1T2S If any of these are missing or damaged, please contact your dealer immediately. If possible, retain the carton including the original packing...
  • Page 5: Requirements

    2. Requirements The Industrial Managed Switch provides remote login interface for management purposes. The following equipment is necessary for further management: z Workstations running Windows XP/2003/Vista/7/8/2008/10, MAC OS X or later, Linux, UNIX, or other platforms are compatible with TCP/IP Protocols. z Workstations are installed with Ethernet NIC (Network Interface Card) z Serial Port Connection (Terminal) ...
  • Page 6: Wiring The Power Inputs

    1 2 3 4 5 6 1A@24V 1 2 3 4 5 6 Fault Figure 3-1: IGS-5225-8P2S/IGS-5225-8P4S/IGS-5225-8P2T2S/IGS-5225- 4UP1T2S Upper Panel  IGS-5225-4T2S: 12~48V DC, 24V AC 1 2 3 4 5 6 1A@24V V2+ V2- Input DC12~48V AC 24V Figure 3-2: IGS-5225-4T2S Upper Panel...
  • Page 7 2. Tighten the wire-clamp screws for preventing the wires from loos- ening. Power 1 Power 2 Positive (+) Pin Negative (-) Pin IGS-5225 Series Pin 1/5 Pin 2/6 The wire gauge for the terminal block should be in the range from 12 to 24 AWG. Note...
  • Page 8: Terminal Setup

    4. Terminal Setup To configure the system, connect a serial cable to a COM port on a PC or notebook computer and to RJ45 type serial (console) port of the Industrial Managed Switch. The console port of the Industrial Managed Switch is DCE already, so that you can connect the console port directly through PC without the need of null modem.
  • Page 9: Logging On To The Console

    5. Logging on to the Console Once the terminal has been connected to the device, power on the Industrial Managed Switch and the terminal will display “running testing procedures”. The following terminal configuration of IGS-5225-8P4S is taken for an example. Note Then, the following message asks to log in user name and password. The default user name and password are shown as follows and the login screen in Figure 5-1 appears User name: admin...
  • Page 10 The user can now enter commands to manage the Industrial Managed Switch. For a detailed description of the commands, please refer to the following chapters. 1. For security reason, please change and memorize the new password after this first setup. 2. Only accept command in lowercase letter under Note console interface.
  • Page 11: Configuring Ip Address

    6. Configuring IP address The Industrial Managed Switch is shipped with default IP address shown below: IP Address: 192.168.0.100 Subnet Mask: 255.255.255.0 To check the current IP address or modify a new IP address for the Switch, please use the procedure as follows:  Display of the current IP Address 1. At the “#” prompt, enter “show ip interface brief”. 2. The screen displays the current IP address shown in Figure 6-1.
  • Page 12  Configuration of the IP Address 3. At the “#” prompt, enter the following command and press <Enter> as shown in Figure 6-2. IGS-5225-8P4S# configure terminal IGS-5225-8P4S (config)# interface vlan 1 IGS5225-8P4S (config-if-vlan)# ip address 192.168.1.100 255.255.255.0 The previous command would apply the following settings for the Industrial Managed Switch. IP Address: 192.168.1.100 Subnet Mask: 255.255.255.0 Figure 6-2: Configuring IP Address Screen 4. Repeat step 1 to check if the IP address has changed.
  • Page 13  Store the current switch configurationn 5. At the “#” prompt, enter the following command and press <Enter>. # copy running-config startup-config Figure 6-3: Saving Current Configuration Command Screen If the IP is successfully configured, the Industrial Managed Switch will apply the new IP address setting immediately. You can access the Web interface of the Industrial Managed Switch through the new IP address. If you are not familiar with the console command or the related parameter, enter “help”...
  • Page 14: Starting Web Management

    7. Starting Web Management The following shows how to start up the Web Management of the Industrial Managed Switch. Note the Industrial Managed Switch is configured through an Ethernet connection. Please make sure the manager PC must be set to the same IP subnet address. For example, the default IP address of the Industrial Managed Switch is 192.168.0.100, then the manager PC should be set to 192.168.0.x (where x is a number between 1 and 254, except 100), and the...
  • Page 15 Default IP Address: 192.168.0.100 Default User Name: admin Default Password: admin Figure 7-2: Login Screen 3. After entering the password, the main screen appears as shown in Figure 7-3. Figure 7-3: Web Main Screen of Industrial Managed Switch...
  • Page 16 4. The Switch Menu on the left of the Web page lets you access all the functions and status the Industrial Managed Switch provides. Now, you can use the Web management interface to continue the Switch management. Please refer to the user manual for more. If you are not familiar with Switch functions or the related parameter, press “Help icon”...
  • Page 17: Saving Configuration Via Web

    8. Saving Configuration via Web In the Industrial Managed Switch, the running configuration file stores in the RAM. In the current version, the running configuration sequence of running-config can be saved from the RAM to FLASH by executing save startup config command, so that the running configuration sequence becomes the startup configuration file, which is called configuration save.
  • Page 18: Resetting The Switch To Default

    10 seconds. After the device is rebooted, you can log in the management Web interface within the same subnet of 192.168.0.xx and default password. Be noted that all the previous setups will be disappeared after the factory default reset is made. P2 FAULT Ring R.O. Reset RESET 115200,N,8,1 1000 LNK/ACT Figure 9-1: IGS-5225-4T2S Reset Button...
  • Page 19 Console P2 FAULT Ring R.O. I/O 115200,N,8,1 1000 LNK/ACT 1000 LNK/ACT PoE Power Usage 240W 100/1000X SFP 180W 120W Reset RESET PoE In-Use Figure 9-2: IGS-5225-8P2S/IGS-5225-4UP1T2S Reset Button PoE-in-Use 802.3at PoE+ Reset IGS-5225-8P2T2S RESET Figure 9-3: IGS-5225-8P4S/IGS-5225-8P2T2S Reset Button...
  • Page 20: Customer Support

    10. Customer Support Thank you for purchasing PLANET products. You can browse our online FAQ resource on PLANET web site first to check if it could solve your issue. If you need more support information, please contact PLANET switch support team.