Flash On Time - Datalogic QuickScan I QD2400 Product Reference Manual

General purpose handheld area imager bar code reader
Table of Contents

Advertisement

References

Flash On Time

This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900
milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments.
Follow these instructions to set this feature.
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to yield
two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3. Go to
page 74
and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming
Mode.
4. Scan the bar code: SELECT FLASH ON TIME SETTING.
5. Scan the appropriate two digits from the keypad in
was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save
the entry string. You can then start again at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See
Table 41. Flash On Time Setting Examples
STEP
ACTION
1
Desired Setting
Divide by 100 (and pad with
2
leading zeroes to yield two
digits)
3
4
Scan Two Characters From
5
Appendix D, Keypad
6
232
Appendix D, Keypad
Table 41
for examples of how to set this feature.
500ms
05
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT FLASH ON TIME SETTING
'0' and '5'
Scan ENTER/EXIT PROGRAMMING MODE
representing the duration which
EXAMPLES
1,000ms (1 sec.)
5200ms (5.2 sec.)
10
52
'1' and '0'
'5' and '2'
9,900ms (9.9 sec.)
99
'9' and '9'