Enter/Exit Programming Mode

PDF417 Set Length 2

This feature specifies one of the bar code lengths for
length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar
code's check, data, and full-ASCII shift characters. The length does not include start/stop characters. Characters
can be set from 01 to 2,710 characters (pad with zeroes) in increments of 01. Any value greater than 2,710 will be
considered to be 2,710.
See
page 217
for detailed instructions on setting this feature.
$CP4L2
Select PDF417 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
190
DEFAULT
PDF417 Length
Control. Length 2 is the maximum label
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code
at left followed by the digits from the Alphanumeric
Appendix D, Keypad
characters in
desired character(s). End by scanning the ENTER/EXIT
bar code again.
~
Length 2 is 2,710 Characters
representing your
CANCEL