Safety

2
Safety
2.1

Intended use

The safety guard locking device is used to monitor the position of the gate on a moveable
guard. A guard locking device can be used as an option. However, it is independent of the
state of the safety outputs.
The system is not intended to implement an application where personal protection is re-
quired.
Safety function of safety switch:
}
Interlocking guard with interlock function,
Together with the control system of the machine, the following functions can be per-
formed:
– The hazardous machine functions are not accessible due to the guard,
– These hazardous machine functions cannot operate until the guard is closed;
– The guard remains closed until the risk due to the not accessible, hazardous machine
– When the guard is closed, the hazardous machine functions that cannot be reached
}
When the actuator is outside the assured release distance S
22 are switched off. The hazardous machine function cannot be implemented.
The safety switch meets the requirements in accordance with:
}
EN 60947-5-3 with one of the approved actuators,
}
EN IEC 62061,
}
EN ISO 13849-1,
}
EN ISO 14119: (Coding level and design)
as specified in the explanatory notes for the
The safety switch may only be used with one of the approved actuators.
}
There is a high signal at safety outputs 12 and 22 if the following occur simultaneously:
– The actuator is detected and
– The inputs S11 and S21 are supply a high signal.
The safety level is achieved only when
}
the safety outputs use 2-channel processing.
The safety guard locking device can be operated in two ways:
}
Conditional unlocking
The safety guard locking device prevents the safety gate from being unlocked while there
is any hazard within the danger zone.
The guard locking device can be deactivated irrespective of the state of the safety out-
puts.
Operating Manual PSEN sl2-IL1/2/3-P
1005909-EN-02
functions has disappeared;
due to the guards can be executed. (The closure of the guard do not by itself start the
hazardous machine functions).
, the safety outputs 12 and
ar
safety-related characteristic data [