Operation
Guard locking controlled with SDD commands
}
If guard locking is controlled with SDD commands, the lighting behaviour of the "Lock"
LED is no longer primarily dependent on the switching state 31/Y1. The status of guard
locking is displayed using LED.
}
If guard locking cannot be activated with SDD commands (e.g. no actuator detected), this
is indicated for 10 seconds, as specified in the table. Then it is switched back to normal
condition. There is no display of the unsuccessful activation attempt.
}
If guard locking cannot be activated with SDD commands, and the actuator is detected,
this is indicated as specified in the table.
11.1

Normal operation

Inputs
S11
S21
31/Y1
-
-
-
No
High High
Low
No
Low
Low
Low
No
High High
High
No
Low
Low
High
No
Operating Manual PSEN sl2-IL1/2/3-P
1005909-EN-02
Actu-
Outputs
ator
detec-
ted
Y32
12+
22
-
Low
Low
Low
Low
Low
Low
Low
Low
Low
Guard
LED indicators
lock-
ing
status
Inact-
ive
Gree
Yel-
n
low
Inact-
ive
Gree
n
Inact-
ive
Gree
n
Inact-
ive
Gree
n
Inact-
ive
Gree
n
Meaning/remedy
The safety switch is
started. A self-test is
carried out as part of
Yel-
Gree
the start procedure.
low
n
Safety gate open, actu-
ator not detected,
guard locking deactiv-
Yel-
ated.
low
Safety gate open, actu-
ator not detected,
guard locking deactiv-
ated,
safety inputs S11 and
S21 are low.
Safety gate open, actu-
ator not detected,
guard locking deactiv-
Yel-
Red
ated,
safety inputs S11, S21
low
and input 31/Y1 are
high.
Safety gate open, actu-
ator not detected,
guard locking deactiv-
Red
ated,
input 31/Y1 is high.