10
IMPORTANT - EASY DE-CALC
20
21
900 ml
22
900 ml
23
Note: If you are performing the EASY DE-CALC procedure immediately after ironing, unplug the
appliance and let it cool down for at least two hours before you perform the procedure.
It is very important to use the EASY DE-CALC function as soon as the EASY
DE-CALC light starts to flash (Fig. 20) and the appliance beeps continuously.
The EASY DE-CALC light flashes and the appliance beeps continuously after
about a month or 10 ironing sessions to indicate that the appliance needs to be
descaled. Perform the following EASY DE-CALC procedure before you continue
ironing.
1
Remove the plug from the wall socket.
2
Place the appliance on the edge of the tabletop.
3
Hold a cup (with a capacity of at least 900ml) under the EASY DE-CALC
knob and turn the knob anticlockwise (Fig. 21).
4
Remove the EASY DE-CALC knob and let the water with scale particles flow
into the cup (Fig. 22).
5
When no more water comes out of the appliance, reinsert the EASY DE-
CALC knob and turn it clockwise to fasten it (Fig. 23).
6
You can continue using your iron immediately after completing the EASY
DE-CALC procedure.