3. EQUIPMENT SETUP
Menu item
[Transducer Setup
Type]
[Model Number]
[High Frequency Min]
[High Frequency Max] Display the high frequency maximum.*
[Low Frequency Min]
[Low Frequency Max]
[Restore Default Set-
tings]
[Frequency Adjust
HF]
[Frequency Adjust LF]
*: Shown with connection of DFF3.
When [Transducer Setup Type] is set to [Model] and connected to DFF3, DFF3-UHD
Menu item
[TX Mode HF]
[High Frequency]
[Frequency Adjust HF]
[CHIRP Width HF]
[TX Mode LF]
[Low Frequency]
[Frequency Adjust LF]
[CHIRP Width LF]
3-18
Description
Select the type of transducer connected.
When the connected sounder is a DFF1-UHD and the
transducer has a compatible TDID, [TDID] is automati-
cally selected.
Note: When the transducer model is changed or TDID is
detected, the frequency and bandwidth set on [Manual] is
to be reset.
• [Manual]: Manually set up the transducer.
• [Model]: Select the appropriate transducer model
(for FURUNO or AIRMAR transducers).
Select the appropriate model number from the list.
Note: Only available when [Transducer Setup Type] is set to [Model].
Display the high frequency minimum.*
Display the low frequency minimum.*
Display the low frequency maximum.*
Restore all menu settings to default.
Fine-tune the high-frequency TX frequency to eliminate
interference (setting range: -50 to +50). Set to [0] where
there is no interference.
Note: These menu items appears when the DFF3,
DFF3-UHD is connected.
Description
Band adjustment mode for center
frequency and CHIRP frequency of
the transducer connected to the
high frequency side.
Set the high frequency (kHz) of the transducer connected to the high fre-
quency side.
*1
*2
If
or
is selected at [TX Mode HF], fine-tune the high-frequency TX fre-
quency to eliminate interference (setting range: -50 to +50). Set to [0]
where there is no interference.
If *1 is selected in [TX Mode HF], set the CHIRP frequency band of the
transducer connected to the high frequency side.
Band adjustment mode for center
frequency and CHIRP frequency of
the transducer connected to the
low frequency side.
Set the low frequency (kHz) of the transducer connected to the low fre-
quency side.
*1
*2
If
or
is selected at [TX Mode LF], fine-tune the low-frequency TX fre-
quency to eliminate interference (setting range: -50 to +50). Set to [0]
where there is no interference.
If *1 is selected in [TX Mode LF], set the CHIRP frequency band of the
transducer connected to the low frequency side.
(setting range)
[Manual],
[Model]
[OK], [Cancel]
-50 to +50
-50 to +50
Options (setting range)
[Auto CHIRP], [FM (Manual
*1
CHIRP)]
, [CW (Fixed Frequen-
*2
cy)]
[Auto CHIRP], [FM (Manual
*1
CHIRP)]
, [CW (Fixed Frequen-
*2
cy)]
Options