Menu item
[High Frequency]
[Transducer Power HF]
[Band Width (HF)]
[Low Frequency]
[Transducer Power LF]
[Band Width (LF)]
When [Transducer Setup Type] is set to [Manual] and connected to DFF3-UHD
Menu item
[TX Volt HF]
Not available (grayed out).
[TX Volt LF]
Not available (grayed out).
[High Frequency]
Set the frequency (kHz) of the transducer connected to the high frequency side.
[Low Frequency]
Set the frequency (kHz) of the transducer connected to the low frequency side.
Set the power of the transducer connected to the high frequency side.
[Transducer  
Power HF]
Set the power of the transducer connected to the low frequency side.
[Transducer  
Power LF]
Motion sensor menu
The [Motion Sensor] menu sets up the motion sensor, which provides for stable dis-
play of the seabed, schools of fish, etc. in moderate-to-rough seas.
Note 1: TZT2BB does not support heaving correction. Motion sensor setup is not re-
quired if [Fish Finder Source] in the [Sounder] menu is set to [Internal].
Note 2: To use the heaving function, the following settings are required at the satellite
compass. For the setting procedure, see the operator's manual for your satellite com-
pass. Settings for SC-30 are done from the [IF-NMEASC] menu, settings for SC-50/
110 are done from the [DATA OUT] menu.
When [Transducer Setup Type] is set to [Manual]
Set the kHz frequency for high frequency. Setting ranges vary
depending on the transducer connected.
Note: Shown with connection of internal fish finder, DFF1, BBDS1,
DFF3, DFF1-UHD.
Set the transmission power for high frequency.
Note 1: Shown with connection of internal fish
finder, DFF1, BBDS1.
Note 2: For DFF1-UHD users, when the connect-
ed transducer TDID is not supported by the DFF1-
UHD, the setting is fixed as [1000].
Set the bandwidth for high frequency.
Note: Shown with connection of DFF3.
Set the kHz frequency for low frequency. Setting ranges vary
depending on the transducer connected.
Note: Shown with connection of internal fish finder, DFF1, BBDS1,
DFF3, DFF1-UHD.
Set the transmission power for low frequency.
Note 1: Shown with connection of internal fish
finder, DFF1, BBDS1.
Note 2: For DFF1-UHD users, when the connect-
ed transducer TDID is not supported by the DFF1-
UHD, the setting is fixed as [1000].
Set the bandwidth for low frequency.
Note: Shown with connection of DFF3.
Description
Description
3. EQUIPMENT SETUP
Options
(setting range)
[600], [1000]
[600], [1000]
3-19