5. Testing

Running Network Tests

Network tests require the participation of your network service provider.
To access the Network & DSX-1 Tests screen, follow this menu selection
sequence:
Use the Command column to start or stop a test. When the Status column shows
that a test is Inactive, Start is displayed; when a test is Active, Stop is displayed.
Position the cursor at the desired Start or Stop command and press Enter. The
Results column displays the test duration.
When the Send and Monitor 511 test is active, ResetMon is available to reset
the error counter to zero.
Selecting Abort All Tests from the Test menu will not disrupt a Send and
Monitor 511 test.
5-2
Main Menu
Test
Network & DSX-1 Tests
main/test/network_DSX1
Slot: 4
Test
--------------------------------------------------------------------------------
Local Loopbacks
Line Loopback:
DSX-1 Repeater Loopback:
DSX-1 DTE Loopback:
Remote Loopbacka
Send Line Loopback: Down
Pattern Tests
Send and Monitor 511
--------------------------------------------------------------------------------
Ctrl-a to access these functions, ESC for previous menu
ResetMon
February 2001
NETWORK & DSX-1 TESTS
Command
Status
Results
Start
Inactive
00:00:00
Start
Inactive
00:00:00
Start
Inactive
00:00:00
Send
Inactive
00:00:00
Stop
Active
hh:mm:ss - Errors 99999+
Hotwire
Model: 8774
MainMenu
Exit