Self-Test Results Messages; Test Status Messages - Paradyne Hotwire 8774 User Manual

Tdm sdsl termination unit with dsx-1 interface
Hide thumbs Also See for Hotwire 8774:
Table of Contents

Advertisement

Self-Test Results Messages

The results of the last power-on or reset self-test appear in the middle column of
the System and Test Status screen.
Table 4-2.

Test Status Messages

The Test Status messages in the following table appear in the right column of the
System and Test Status screen.
Table 4-3.
For information on testing, refer to
8774-A2-GB20-40

Self-Test Results Messages

Message
What Message Indicates
CPU Failed
The CPU failed internal
testing.
Device Failed
One or more of the unit's
integrated circuit chips has
failed device-level testing.
DSX-1 Failed, Pt n
The unit failed to internally
loop data on the DSX-1
Port n .
Failure xxxxxxxx
An internal failure occurred.
(xxxxxxxx represents an
8-digit hexadecimal failure
code for use by service
personnel.)
Memory Failed
The unit failed memory
verification.
Net DSL Failed, Pt n
The unit failed to loop data on
the network DSL circuit of
Port n .
Passed
No errors were detected.

Test Status Messages

Test Status Message
Meaning
511 Test Active, Pt n
A 511 Test and Monitor is active on the DSL Port n network
interface.
DLB Test Active, Pt n
A Data Terminal Loopback test is active on Port n .
Lamp Test Active
The Lamp Test is active, causing the LEDs on the front panel
to light.
LLB Test Active, Pt n
A network Line Loopback test is active on Port n .
No Test Active
No tests are currently running.
RLB Test Active, Pt n
A network Repeater Loopback test is active on Port n .
February 2001
What To Do
1. Reset the unit and try again.
2. Call your service
representative for
assistance.
Record the failure code and
contact your service
representative.
1. Reset the unit and try again.
2. Call your service
representative for
assistance.
No action is needed.
Chapter 5, Testing
.
4. Monitoring the Unit
4-5

Advertisement

Table of Contents
loading