Device Messages

The Device Messages in
may appear in the messages area at the bottom of the ATI screens.
Table 6-1.
8774-A2-GB20-40
Table 6-1, Device
Device Messages (1 of 2)
Device Message
What Message Indicates
Access level is
The operator requested that
Operator.
configuration options be
Configuration is
loaded, but does not have
read-only.
authority to edit them.
Cannot Save – no
All of the login IDs being
Login IDs with Access
saved have an access level
Administrator
below Administrator.
Command Complete
Action requested has
successfully completed.
Invalid Character ( x )
A nonprintable ASCII
character ( x ) has been
entered.
Invalid Password
Login is required and an
incorrect password was
entered; access is denied.
Invalid – Send Pattern
A pattern test was already in
Already Active
progress when the Start field
was selected.
Invalid – [Test] Already
The described test was
Active
already in progress when
another selection was made.
Invalid Test
A loopback or pattern test
Combination
was in progress when Start
was selected to start another
test, or was active on the
same or another interface
when Start was selected.
IP address not in
The Peer IP address
MCC subnet
specified is not in the same
nnn.nnn.nnn.nnn
subnet as the MCC.
February 2001
6. Messages and Troubleshooting
Messages, listed in alphabetical order,
What To Do
If configuration options are to be
edited, use a Login ID that has
Administrator authority.
Change the access level of at
least one Login ID to
Administrator so that
configuration changes can be
made. (Operator-level users
cannot make configuration
changes.) Save the Login IDs.
No action needed.
Reenter information using valid
characters.
T
Try again.
T
Contact your system
administrator to verify your
password.
T
Allow test to continue.
T
Select another test.
T
Stop the test.
T
Allow test to continue.
T
Select another test.
T
Stop the test.
T
Wait until other test ends and
message clears.
T
Abort all tests from the Test
menu screen.
T
Stop the test from the same
screen the test was started
from.
Enter an IP address that is in
the same subnet as the MCC.
6-3