Send And Monitor 511 - Paradyne Hotwire 8774 User Manual

Tdm sdsl termination unit with dsx-1 interface
Hide thumbs Also See for Hotwire 8774:
Table of Contents

Advertisement

Send and Monitor 511

The Send and Monitor 511 test causes the local and remote units to send a 511
test pattern to each other. The front panel Test LEDs of both units are on during
the test. The duration and results of the test are displayed on the Network & DSX-1
Tests screen of the initiating unit.
T1
LIU
AIS
Framer
Procedure
To run a Send and Monitor 511 test:
When a Send and Monitor 511 test is active, a count of bit errors is displayed next
to the test duration, and the ResetMon virtual function key is available for use.
Type r or R or select the ResetMon virtual function key to reset the error count.
8774-A2-GB20-40
NOTE:
The Send and Monitor 511 test is not a loopback test. Each unit independently
sends and monitors a 511 pattern.
511
CAP
Pattern
CAP
511
Gen
511
Pattern
511
Mon
Framer
Transceiver
1. Position the cursor at the Start command next to Send and Monitor 511 on the
Network & DSX-1 Tests screen.
2. Press Enter.
The Start command is changed to Stop.
3. To manually stop the test, verify that the cursor is positioned at the Stop
command.
4. Press Enter.
February 2001
CAP
CAP
511
Mon
511
Gen
Framer
Framer
Transceiver
5. Testing
T1
AIS
DSX-1
LIU
Port
98-16108
5-7