Malfunction Indication And Solution - Zmotion ZMIO310 Manual

Verticale bus expansion module
Table of Contents

Advertisement

firmly connected.

3.1.6. Malfunction Indication and Solution

Status Indication Light
POW
RUN
ERR
ON
twinkle alternately
and slowly
ON
twinkle alternately
and rapidly
ZMIO310 Vertical Bus Expansion Module User Manual V1.0
Reason
The communication
between EtherCAT
master station and
coupler module breaks
The pre-scanned sub
module and actual
continuation sub
module are not totally
matched.
Solution
Check if crystal head is loosened or not
Check the net cable is damaged or not
Restart the power.
Check if the continuation submodule is
lost, or be in malfunction
Check if appears hot plug or discharger
Restart the power.