Unit; Table 2 Unit Corrective Maintenance - Pace PROGRAMMABLE THERMOFLO Operation & Maintenance Manual

Table of Contents

Advertisement

UNIT

Most malfunctions are simple and easy to correct. Select the "Symptom" which best describes the malfunction
and follow the steps given in the "Solution" column.
Symptom
No power to system.
Heater Assembly does not
heat. No malfunction indicated
on Digital Readout. Green GFI
light is on.
Little or no air flow, heater
heats and blower is running.
Display on Digital Readout
indicates a malfunction.
Vacuum Cup will not hold
component.
Vacuum Pickup Rod binding. Vacuum Pickup rod is bent.
For further assistance, contact the PACE Service Department at
Table 2. Unit Corrective Maintenance
CORRECTIVE MAINTENANCE
Probable Cause
Blown Fuse (F1).
Line cord unplugged.
Open Heater.
Kinked air hose.
Worn or broken vacuum cup. Replace vacuum cup.
Tel. (301) 490-9860 or FAX (301) 483-7030.
Solution
Replace Fuse F1 located on the power
source rear panel.
Plug line cord into AC outlet.
Contact PACE Service department for
assistance.
Change routing of air hose to remove
kinks.
Refer to Digital Readout Message
Codes, Table I.
Contact PACE Service Department fo
assistance.