Thermoflo Handpiece; Optional Accessories - Pace PROGRAMMABLE THERMOFLO Operation & Maintenance Manual

Table of Contents

Advertisement

THERMOFLO HANDPIECE

25. VACUUM PICK SWITCH - Activates & deactivates
vacuum pump supply to the Vacuum Pick Assembly.
Switch must be depressed for a period of 0.5 second
before circuit deactivation; activation is immediate.
26. CYCLE SWITCH - Activates reflow cycle (heat & air
flow). Switch must be held to maintain activation in
Manual Mode; in Timed & Program Modes, switch is
pressed & released to initiate set cycle time. Switch can
be used to abort cycle in Timed or Program Mode
operation.
27. VACUUM PICK ADJUST CONTROL - Provides
adjustment for height of Vacuum Pick Assembly (&
Vacuum Cup). Turn clockwise to raise pick or
counterclockwise to lower pick.
28. VACUUM PICK ASSEMBLY - Provides a means to
lift or place components.
29. HEAT SHIELD-Protects the operator from
unintentional contact with the heater.
30. VACUUM CUP - Provides positive holding of
components for positioning during the replacement
process and for lifting of the component during the
removal process.
31. NOZZLE ASSEMBLY - Directs heated air from the
heater assembly to the solder joint areas for soldering or
desoldering of components. Nozzles are optional parts
ordered for a specific application.
32. QUICKFIT NOZZLE ADAPTER - Allows quick
nozzle attachmentand release.

OPTIONAL ACCESSORIES

33. OPTIONAL ACCESSORIES - Optional accessories
such as a Work Platform, preheating system, lighting
and vision attachments fume extraction and board
holders are available. Accessories are described in
"Systems & Accessories" located in the Replacement
Parts section of this manual.
GENERAL INFORMATION
Figure 3.
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Prc 1500Prc 1500eTf 200Tf 200eTf 500Tf 500e

Table of Contents