Program Component Installation - Pace PROGRAMMABLE THERMOFLO Operation & Maintenance Manual

Table of Contents

Advertisement

OPERATION

PROGRAM COMPONENT INSTALLATION

1. If the unit is being used with the handpiece mounted on the ThermoFlo work platform, install the PCB
on the work platform, in the Work Holder or the optional HS 200 preheating unit. Position PCB with
the component land pattern directly beneath and squared to the nozzle.
If the HS 200 Heat Wave system is being used for preheating, ensure that
the system is properly set up (with a control cable connected between the
Heat Wave Power source and the Heat Wave Connector on the rear panel
of the ThermoFlo power source) and preheater is at the proper temperature.
2. Set the unit POWER Switch (on rear panel of power source) to the ON
position.
3. Install the proper Nozzle Assembly and Vacuum Cup onto the handpiece.
Ensure that the PCB assembly to be reworked and any replacement
component have been properly prepared. Refer to the "General Process
Guidelines" portion of this manual.
4. Adjust the vacuum cup up into the nozzle using the Vacuum Pick Adjust
Control.
54
NOTE
Figure 63.
Figure 64.