TIMED MODE OF OPERATION

REMOVAL
The ThermoFlo System Work Platform (PACE
part number 6018-0099) is optionally available
to assist in the installation/removal process.
1. Install proper Nozzle & Vacuum Cup (if required) into ThermoFlo
Handpiece.
2. Turn Power Switch ON. Press MODE/ESC Key until Timed Remove
Mode Light illuminates.
3. Adjust Set Temperature, Blower Speed and Cycle Time as desired using
Scroll Keys. See
4. If using Vacuum Cup, adjust the cup (using the Vacuum Pick Adjust
Control) to a point where the bottom of the cup is flush with the bottom
edge of the nozzle. See
5. Lower Nozzle over component (slightly above component leads) to
direct air flow to solder joints. Ensure contact between the vacuum cup
and the component.
6. Press and release handpiece Cycle Switch to initiate reflow cycle. See
Five seconds prior to cycle completion,
vacuum will activate automatically.
7. When cycle is complete, lift handpiece.
8. Place handpiece over heat resistant surface. Press and hold Vacuum
Switch for 1/2 second to turn vacuum off and release component.