Mounting The Locking Counterpart; Check The Electric Swing Bolt 842-Sa1; Installation On Glass Surfaces - Assa Abloy effeff 842-SA1 Installation And Mounting Instructions

Door dead bolts
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 20
A
Mounting

Mounting the locking counterpart

1
Make the recess and all holes for the locking counterpart (Fig. 6, page 93).
2
Clean the recess and all holes by blowing or vacuuming them clean.
3
Screw on the supplied locking counterpart (Fig. 7, page 94).
4
Make sure that the rebate gap is no less than 3 mm and no more than 8 mm.
5
Check the door to ensure it moves freely.
 The locking counterpart is mounted.

Check the electric swing bolt 842-SA1

1
Test all functions of the swing bolt.
 The electric swing bolt 842-SA1 is fully mounted and ready for use.

Installation on glass surfaces

Optionally, the electric motorized swing bolt 842-SA1 or the locking counterpart can be mounted in a
surface-mounted casing ("Accessories", page 36) and glued onto a glass door or glass surface.
Installation can take place both vertically and horizontally (locking at the bottom). With horizontal
installation, you should select a position as near as possible to the lock side on the door to ensure little
leverage is required.
At tention!
Restricted movement if the gap to the vertical frame section is incorrect: If the gap to the vertical
frame section is too small, the door can no longer move freely and can no longer be fully opened.
EN