28

Signalling

LED signal
Slowly flashing yellow
Solid blue light
Purple solid or flashing light
Solid orange light
Solid yellow light
Rapid flashing red
Slowly flashing blue
Slow flashing red
Slowly flashing red and blue
Rapid flashing red and blue
Fault
Voltage drop under load
Bolt jammed
Motor overcurrent
Voltage too high
Undervoltage or extreme
overvoltage
2-wire unlocking timeout
Temperature too low
Temperature too high
System fault warning
Critical system failure
Required action
Measure voltage drop on the bolt
under load during locking.
The voltage should remain stable
under load.
Check for centring with the strike
plate or blockage.
Check that the door works and that
the side pressure is not too high.
Measure voltage at bolt. Require-
ment 11-26V.
Reduce the side pressure of the door
to enable the bolt to be unlocked via
spring power.
Check environmental conditions
Requirement -10 to 55°C.
Bolt is nearing the end of its service
life – replace bolt.
Fail-unlocked bolt goes into de-ener-
gised state – replace bolt.