Quick Links

Electronic Battery Operated Security Solution
Operational Modes
Secure
Normal locked state. Any
assigned user code can gain
access. Lock/re-lock
automatically.
NOTE TO INSTALLER
NOTE TO INSTALLER
FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO THE LOCK AND
FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO THE LOCK AND
VOID THE FACTORY WARRANTY.
VOID THE FACTORY WARRANTY.
Finish Care
This lockset is designed to provide the highest standard of product quality and performance. Care should
be taken to insure a long-lasting finish. When cleaning is required use a soft, damp cloth. Using lacquer
thinner, caustic soaps, abrasive cleaners or polishes could damage the coating and result in tarnishing.
An ASSA ABLOY Group brand
Exit Keypad Lock Installation Instructions
886F & 896F Series
Lockout
Lockset will not accept any
assigned user codes except
for the Supervisor and
Emergency Codes.
®
FEATURES
Battery Operated (Hardwire Capable)
Motorized Grade 1 Exit Trim
94 User Code Capacity
All Metal Escutcheon and
Pushbuttons
LED Function Indicator
Patented Free-Wheeling Levers
(Patent # 4,920,773)
Self-Adjusting for Door Thickness
Weather Resistant
ADA Compliant 12-Button Keypad
Modular Design
(Simple Installation)
Audible Pushbutton
Patented Keypad Blinders
(Patent # 7,091,429)
Request to enter input
Emergency, Supervisor, Passage,
Lockout and Master Codes
Passage
Maintains unlocked state.
Relocks by entering passage
code the second time
80-8420-0900 Rev. B (05-08)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Yale eBoss 886F Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Assa Abloy Yale eBoss 886F Series

  • Page 1 When cleaning is required use a soft, damp cloth. Using lacquer thinner, caustic soaps, abrasive cleaners or polishes could damage the coating and result in tarnishing. 80-8420-0900 Rev. B (05-08) An ASSA ABLOY Group brand...
  • Page 2: Table Of Contents

    -C Re-Keying/Competitor Cylinder/ Important Cylinder Data........ Section The Install ....................-A Install The Trim....................-B Exit Device Cover Installation ................-C Install Electric Components................Section Electrical Connections and Testing............. Section Troubleshooting....................Template..........................80-8420-0900 Rev. B (05-08) An ASSA ABLOY Group brand...
  • Page 3: Section Prepare The Door

    Drill the remainder of the holes again ½ way thru the door. Note: To avoid splintering wood doors, drill c. Repeat steps a & b on the back face of the door. holes from both sides. 80-8420-0900 Rev. B (05-08) An ASSA ABLOY Group brand...
  • Page 4: I -B Locate And Drill Holes For Electronic Components

    Hinges on right, opens left, opens outward. For outward. For handed handed locks, specify locks, specify RHR. LHR. If the lock body is not correct hand, See Section on Page 5 80-8420-0900 Rev. B (05-08) An ASSA ABLOY Group brand...
  • Page 5: A How To Change Hands (Standard Cylinder Locks)

    Step 3 Rotate the Lockbody (See step 3 above) Step 4 Reassemble (See step 4 above) Rotate Handle & Retaining Replace Handle & Retaining Ring Ring 180° in this Position. 80-8420-0900 Rev. B (05-08) An ASSA ABLOY Group brand...
  • Page 6 Schlage Connecting ® Roll Pin Bar when assembled Follow instructions above to install cylinder 99-9999-3942-999 toward free end of into lever handle. Schlage® Cylinder Cam (.094 Dia. x .375) handle 14-5407-1036-048 80-8420-0900 Rev. B (05-08) An ASSA ABLOY Group brand...
  • Page 7: Section Iii The Install

    Use the combo screws to surface apply the exit device head to the door. Continue with the device instructions and install the end cap. 80-8420-0900 Rev. B (05-08) An ASSA ABLOY Group brand...
  • Page 8: B Exit Device Cover Installation

    Step 12 Install the electronics cover using the short #8-32 flathead screws. Figure 7 Step 13 Inspect your work. Insure everything was installed correctly. Step 14 Install the strike and any other components per the exit device instructions. 80-8420-0900 Rev. B (05-08) An ASSA ABLOY Group brand...
  • Page 9: Electrical Connections And Testing

    Refer to the programming guide packaged with the trim. HARDWIRE AND REMOTE INPUT OPTION(s) DIAGRAM 9VDC Power input Remote Entry Input Normally Open Momentary Switch (9 Volt Power Supply) Hardwiring Harnesses 80-8420-0900 Rev. B (05-08) An ASSA ABLOY Group brand...
  • Page 10: Section V Troubleshooting

    If the above tips do not solve your problem please call our Technical Product Support Team at the phone number listed on the back of these instructions. 80-8420-0900 Rev. B (05-08) An ASSA ABLOY Group brand...
  • Page 11: Template

    7/16 1-3/8 Vertical See Device CAUTION: Office copiers and facsimile mach- ines may change the size of a drawing and make Instructions the template inaccurate to use as a door marker. 80-8420-0900 Rev. B (05-08) An ASSA ABLOY Group brand...
  • Page 12 Copyright © 2008,Yale Security Inc. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 80-8420-0900 Rev. B (05-08) An ASSA ABLOY Group brand...