Technical data
Technical data
Technical data
Feature
Power supply
Operating current
Bolt condition monitoring
Door position monitoring
Maximum side pressure of the door
Operating temperature range
Weight
Dimensions (L x W x D)
Protection rating
Required cable cross sections
Distance
Cable cross section
5 m
0.5 mm
10 m
0.75 mm
15 m
1 mm
CE mark
C
11– 26 V DC
Peak: 1000 mA at 12VDC
Standby: 35 mA at 12 VDC with LED activated
Normally closed/normally open contacts (50 mA @
30 VDC)
Normally closed (50 mA at 30 VDC)
Unlocking: 100 kg (3-wire operation)
Locking:
– 10 °C to + 55 °C
750 g
256 mm x 30 mm x 42 mm
IP53
Distance
2
20 m
2
30 m – 50 m
2
ASSA ABLOY
Sicherheitstechnik GmbH
Bildstockstraße 20
72458 Albstadt
DEUTSCHLAND
15 kg (2-wire operation)
20 kg (12 W)
35 kg (24 W)
Cable cross section
1.5 mm
2
2.5 mm
2
EN
35
Need help?
Do you have a question about the effeff 842-SA1 and is the answer not in the manual?