6 OPERATION
44
Check the box in the Delete After Test Column to clear the data after the
successful completion of the test. Note that these fields will not clear on a
fault or after a calibration cycle.
Check the box ID Entry Request on Cycle Start to require the operator to
enter information into these fields at the start of a cycle. If this is not set
up to be required, an operator can still access these data logging fields.
On the main test screen, press the 'Test ID' button and this screen will appear:
Enter the required data by selecting the proper box and using the optional barcode
scanner or the onscreen keyboards. If the ATLAS controller is equipped with a
barcode scanner, then scanning a barcode will enter the contents into the currently
selected box. Entering data into a box will automatically set the next box to active.
This data will appear in the test summary data on the SD card/USB stick as well as
be printed out on the ticket at the end of the test, if so equipped.
There are three different test screens. Based on the application chosen in
advanced settings, different test screens will be displayed.

Hard Vac Operation

The test screen indicates key test data to help the operator to monitor the leak
test. The sidebar on the right of the screen allows the operator to enable/ disable
leak detector details, change recipe, change test ID and data log settings, and
perform a system calibration.