SPX FLOW APV CU4 plus Instruction Manual page 50

24v direct connect control unit
Table of Contents

Advertisement

TÜV NORD CERT GmbH
Hannover Office
Am TÜV 1
30519 Hannover
Germany
For the control unit type CU4* plus 24V Direct Connect:
Internal / External
External
External
Internal
Internal
Internal
Internal
Internal
Internal
Internal
Internal
Internal
Internal
Internal
Internal
Internal
Internal
Internal
External
For the control unit type CU4*plus 24V IO-Link:
Internal / External
External
External
Internal
Internal
Internal
Internal
Internal
Internal
Internal
Internal
Internal
Internal
Internal
External
Internal
P17-F-610
Attachment to IECEx TUN 22.0020X issue No.: 0
Terminal
Designation
1
Power+
2
Power-
3
O0 Digital Output
4
O1 Digital Output
5
O2 Digital Output
6
O3 Digital Output
7
SV Digital Output
8
I0 Digital Input
9
I1 Digital Input
10
I2 Digital Input
11
+5VDC
12
S
13
0V
Linear
Linear
sensor
sensor
Y1
PWM Output
Y2
PWM Output
Y3
PWM Output
Service port
--
Terminal
Designation
1
Power+
2
Power-
3
C /Q
4...10
--
11
5 VDC
12
Sensor 2
13
GND
JST
Sensor 1
14
Sensor 2
15
GND
Y1
PWM Output
Y2
PWM Output
Y3
PWM Output
Service port
--
P
Pressure sensor
Page 3 of 5
Functional description
Power supply 24V d.c. ± 20%
Power supply 24V d.c. (GND)
PLC input valve status / closed
PLC input valve status / open
PLC input valve status / upper seat lift
PLC input valve status / lower seat lift
PLC input service request
PLC output to activate solenoid 1 / main
valve
PLC output to activate solenoid 2 / upper
seat lift
PLC output to activate solenoid 3 / lower
seat lift
Supply voltage for SPX prox. sensor / linear
sensor
Signal SPX prox. sensor
Potential for SPX prox. sensor / linear
sensor
--
Solenoid valve 1 (main valve)
Solenoid valve 2 (upper seat lift)
Solenoid valve 3 (lower seat lift)
Connection serial/USB converter for
CU4plus toolbox software
Functional description
Operating voltage + (18 V...30 V d.c.)
Operating voltage – or Ground
IO-Link Signal
Not in use
Voltage supply for valve sensor or extension
module
Sensor 2 connection or extension module
Mass potential for sensor supply or
extension module
Linear Sensor 1
Sensor Signal 2
Mass potential for sensor supply
Solenoid valve 1 (main valve)
Solenoid valve 2 (upper seat lift)
Solenoid valve 3 (lower seat lift)
Connection serial/USB converter for
CU4plus toolbox software
Pressure measurement of main actuator
Rev. 01 / 06.18

Advertisement