SPX FLOW APV CU4 plus Instruction Manual page 29

24v direct connect control unit
Table of Contents

Advertisement

SPX FLOW
SPX FLOW_CU4.plus. 24V Direct Connect_IECEx_Zone 2_GB-1_012024_for D4. Valves.indd
6.7.1. Mix proof valve D4
Output
signals
O0
O1
DI2
DI3
Input signal
I0
I1
I2
Control Unit
CU4plus Direct Connect
Instruction Manual GB-0
6.
Electronic Module
6.7.
Data signals
valve
linear sensor 2 / (Teach data)
status
sensor signal S1
closed
1
open
0
solenoid 1
solenoid 1
Main
upper seat lift
1
0
operating
main stroke downwards
main stroke
valve operating direction: downwards
lower shaft
signal S3
signal S4
upper shaft
signal S2
signal S1
linear sensor 1
linear sensor 1 / (Teach date)
sensor signal S2
sensor signal S3 sensor signal S4
0
not used
0
not used
solenoid 1
lower seat lift
0
linear sensor 1
valve target
linear sensor 2
valve target
linear sensor 2
tolerance
0
1
GB
M1
M2
band
+1 mm,
-1 mm
+1 mm,
-1 mm
29