6.7.2. Mix proof valve D4 SL
Output
valve status
signals
O0
O1
O2
upper seat lift
O3
lower seat lift
Input signal
I0
I1
I2
30
6.
Electronic Module
6.7.
Data signals
linear sensor 2 / (Teach data)
sensor signal S1
closed
1
open
0
0
1
solenoid 1
solenoid 2
Main
upper seat lift
1
0
0
1
0
0
operating
main stroke downwards
upper seat lift upwards
lower seat lift downwards
main stroke
valve operating direction: downwards
lower shaft
signal S3
signal S4
upper shaft
signal S2
signal S1
linear sensor 1
linear sensor 1 / (Teach data)
sensor signal S2
sensor signal S3 sensor signal S4
0
0
1
0
solenoid 3
lower seat lift
0
0
1
linear sensor 1
linear sensor 2
linear sensor 2
1
0
0
1
1
0
0
0
CU4plus Direct Connect
Instruction Manual GB-0
GB
valve target
M1
valve target
M2
tolerance
band
+1 mm,
-1 mm
+1 mm,
-1 mm
+1 mm,
-1 mm
+1 mm,
-1 mm
Control Unit