Weld-In Adapter With Leakage Hole; Mounting The Device; Required Tool; Installation - Endress+Hauser Liquiphant FTL51B Operating Instructions Manual

Vibronic hart point level switch for liquids
Hide thumbs Also See for Liquiphant FTL51B:
Table of Contents

Advertisement

Liquiphant FTL51B HART
Endress+Hauser
 9
Examples of support in the event of dynamic load
Marine approval: In the case of pipe extensions or sensors longer than 1 600 mm, a
support is needed at least every 1 600 mm.
5.1.6

Weld-in adapter with leakage hole

Weld in the weld-in adapter in such a way that the leakage hole is pointing downwards.
This enables any leaks to be detected quickly.
 10
Weld-in adapter with leakage hole
5.2

Mounting the device

5.2.1

Required tool

• Open-ended wrench for sensor installation
• Allen key for housing locking screw
5.2.2

Installation

Aligning the tuning fork using the marking
The tuning fork can be aligned using the marking. Medium can thus run off easily and
buildup is avoided.
Markings may include the following:
• Material information, thread name or circle on the hexagonal nut or on the weld-in
adapter
• II symbol on the back of the flange or Tri-Clamp
Mounting
A0031874
A0039230
15