Operation
46
9.2

Heartbeat Verification

The "Heartbeat Verification" module contains Heartbeat Verification wizard, which
verifies the current instrument health and creates the Heartbeat Technology verification
report:
• The wizard can be used via the SmartBlue app.
• The wizard guides the user through the entire process for creating the verification
report.
• The operating hours counter and minimum/maximum temperature indicator (peakhold)
are displayed.
• If the oscillation frequency of the fork increases, a corrosion warning appears.
• The as-delivered state of the oscillation frequency in air is indicated on the verification
report. A high oscillation frequency is an indicator of corrosion. A lower oscillation
frequency indicates buildup or a sensor covered by the medium. Deviations of the
oscillation frequency from the oscillation frequency in the as-delivered state can be
caused by the process temperature and process pressure.
9.3

Proof testing for SIL/WHG devices

The proof test is only available for devices with SIL or WHG approval.
The "SIL Proof test" module, the "WHG Proof test" module or the "SIL/WHG Proof test"
module contains a SIL/WHG Prooftest wizard, which must be performed at appropriate
intervals in the following applications: SIL (IEC61508/IEC61511), WHG (German Water
Resources Act (Gesetz zur Ordnung des Wasserhaushalts)):
• The wizard can be used via the SmartBlue app.
• The wizard guides the user through the entire process for creating the verification
report.
• The verification report can be saved as a PDF file.
Time stamp of last proof test
Date of proof test
Frequency at delivery status
Current frequency
Upper alarm frequency
Upper warning frequency
Lower alarm frequency
Battery status
Electronics temperature
Minimum electronics temperature
Maximum electronics temperature
Liquiphant FTL63
Endress+Hauser