14.3.9

Mechanical load

Support the device in the event of severe dynamic load. Maximum lateral loading capacity
of the pipe extensions and sensors: 75 Nm (55 lbf ft).
  For more details, see the "Supporting the device" section.
A

14.3.10 Pollution degree

Pollution degree 2
14.3.11 Electromagnetic compatibility (EMC)
• Electromagnetic compatibility as per EN 61326 series and NAMUR recommendation
EMC (NE21)
• With regard to the safety function (SIL), the requirements of EN 61326-3-x are satisfied
 For more details, refer to the EU Declaration of Conformity.
14.4

Process

14.4.1

Process temperature range

–50 to +150 °C (–58 to +302 °F)
Pay attention to the pressure and temperature dependency.
14.4.2

Thermal shock

≤ 120 K/s
14.4.3

Process pressure range

–1 to +64 bar (–14.5 to 928 psi) for a maximum of 150 °C (302 °F)
WARNING
L
The maximum pressure for the device depends on the lowest-rated element, with
regard to pressure, of the selected component. This means that it is necessary to pay
attention to the process connection as well as the sensor.
Pressure specifications,
Only operate the device within the specified limits!
The Pressure Equipment Directive (2014/68/EU) uses the abbreviation "PS". The
abbreviation "PS" corresponds to the MWP (maximum working pressure) of the device.
 Technical Information, "Mechanical construction" section.