Technical data
56
14.3.2
Storage temperature
–40 to +80 °C (–40 to +176 °F)
Optional: –50 °C (–58 °F), –60 °C (–76 °F)
14.3.3
Humidity
Operation up to 100 %. Do not open in a condensing atmosphere.
14.3.4
Operating altitude
As per IEC 61010-1 Ed.3:
• Up to 2 000 m (6 600 ft) above sea level
• Can be extended to 3 000 m (9 800 ft) above sea level if overvoltage protection is used
14.3.5
Climate class
As per IEC 60068-2-38 test Z/AD
14.3.6
Degree of protection
Testing according to IEC 60529 and NEMA 250
IP68 test condition: 1.83 m H
Housing
See cable entries
Cable entries
• M20 coupling, plastic, IP66/68 NEMA Type 4X/6P
• M20 coupling, nickel-plated brass, IP66/68 NEMA Type 4X/6P
• M20 coupling, 316L, IP66/68 NEMA Type 4X/6P
• M20 coupling, 316L, hygienic, IP66/68/69 NEMA Type 4X/6P
• M20 thread, IP66/68 NEMA Type 4X/6P
• G ½ thread, NPT ½, NPT ¾ IP66/68 NEMA Type 4X/6P
Degree of protection for M12 plug
• When housing is closed and connecting cable is plugged in: IP66/67 NEMA Type 4X
• When housing is open or connecting cable is not plugged in: IP20, NEMA Type 1
NOTICE
M12 plug: Loss of IP protection class due to incorrect installation!
‣
The degree of protection only applies if the connecting cable used is plugged in and
screwed tight.
‣
The degree of protection only applies if the connecting cable used is specified according
to IP67 NEMA Type 4X.
If the "M12 plug" option is selected as the electrical connection, IP66/67 NEMA Type
4X applies for all housing types.
14.3.7
Vibration resistance
As per IEC60068-2-64-2008
2
a(RMS) = 50 m/s
, f = 5 to 2 000 Hz , t = 3 axes x 2 h
14.3.8
Shock resistance
In accordance with IEC60068-2-27-2008: 300 m/s² [= 30 g
g
: standard acceleration of gravity
n
O for 24 h
2
Liquiphant FTL63
] + 18 ms
n
Endress+Hauser