Replace drain plug.
Remove lid assembly.
Remove sleeve.
Clean
Dose with MC1+ Protector
O ring
The lid seal should be cleaned and checked for
wear when servicing MagnaClean. It is Best
Practice to replace the lid and drain valve seals
at each service.
"Only use Silicon grease or water to lubricate
O ring.
Do not use flux or EP grease."
Turn locking pin 90° and remove.
CAUTION: Ensure valves are off
Disconnect.
Remove.
CAUTION: Clean and inspect collets and
lubricate seals with water only.
Fit quick release trigger and canister onto
valves.
CAUTION: Ensure canister is firmly pushed onto
valves until fully engaged.
Replace locking pin and turn 90° to lock
Vymeňte odtokovú zátku.
Demontujte zostavu veka.
Odstráňte puzdro.
Vyčistite.
Dávkujte prostriedkom MC1+ Protector.
O-krúžok
Počas údržby zariadenia MagnaClean by sa
malo vyčistiť tesnenie veka a skontrolovať, či
nie je opotrebované. Osvedčeným postupom je
vymeniť tesnenie veka a vypúšťacieho ventilu
pri každej údržbe.
"Na mazanie O-krúžku používajte iba silikónové
mazivo alebo vodu.
Nepoužívajte spájkovaciu pastu ani EP mazivo."
Otočte zaisťovací čap o 90 stupňov a vyberte ho.
UPOZORNENIE: Skontrolujte, či sú ventily
zatvorené.
Odpojte.
Odstráňte.
UPOZORNENIE: Vyčistite a skontrolujte klieštiny
a tesnenia namažte iba vodou.
Nasaďte spúšťač rýchleho uvoľnenia a nádobu
na ventily.
UPOZORNENIE: Uistite sa, že nádoba je pevne
zasunutá do ventilov, kým nie je úplne zaistená.
Vymeňte zaisťovací čap a otočte ho o 90
stupňov, aby zapadol
33