Servicing
7
Remove sleeve.
1
10
3
O ring
1
The lid seal should be
cleaned and checked
for wear when servicing
MagnaClean. It is Best
Practice to replace the
lid seal at each service.
Only use Silicon grease or
water to lubricate O ring.
Do not use flux or EP
grease.
12
1
8
Clean
Clean
1
2
3
Clean
2
11
Hand
tighten.
13
3
2
1 - Turn valves on.
2 - Vent.
3 - Wipe filter dry.
9
Dose with
MC1+ ™
Protector
12
Tighten by a ¼ turn.
Important - Do NOT
overtighten.