Replace drain plug.
Remove lid assembly.
Remove sleeve.
Clean
Dose with MC1+ Protector
O ring
The lid seal should be cleaned and checked for
wear when servicing MagnaClean. It is Best
Practice to replace the lid and drain valve seals
at each service.
"Only use Silicon grease or water to lubricate
O ring.
Do not use flux or EP grease."
Turn locking pin 90° and remove.
CAUTION: Ensure valves are off
Disconnect.
Remove.
CAUTION: Clean and inspect collets and
lubricate seals with water only.
Fit quick release trigger and canister onto
valves.
CAUTION: Ensure canister is firmly pushed onto
valves until fully engaged.
Replace locking pin and turn 90° to lock
Skift avløpsplugg.
Fjern lokket.
Fjern hylsen.
Rengjør
Dose med MC1+ Protector
O-ring
Lokktetningen skal rengjøres og kontrolleres for
slitasje når du utfører service på MagnaClean.
Det er beste praksis å skifte ut lokket og
avløpsventiltetningene ved hver service.
"Bruk bare silisiumfett eller vann til å smøre
O-ringen.
Ikke bruk fluss- eller EP-fett."
Drei låsepinnen 90° og fjern den.
FORSIKTIG: Kontroller at ventilene er av
Koble fra.
Fjern.
FORSIKTIG: Rengjør og inspiser flenser og smør
tetninger kun med vann.
Monter hurtigutløseren og kannen på ventilene.
FORSIKTIG: Kontroller at kannen skyves fast på
ventilene til den er helt i inngrep.
Bytt låsepinne og drei 90° for å låse
27