Replace drain plug.
Remove lid assembly.
Remove sleeve.
Clean
Dose with MC1+ Protector
O ring
The lid seal should be cleaned and checked for
wear when servicing MagnaClean. It is Best
Practice to replace the lid and drain valve seals
at each service.
"Only use Silicon grease or water to lubricate
O ring.
Do not use flux or EP grease."
Turn locking pin 90° and remove.
CAUTION: Ensure valves are off
Disconnect.
Remove.
CAUTION: Clean and inspect collets and
lubricate seals with water only.
Fit quick release trigger and canister onto
valves.
CAUTION: Ensure canister is firmly pushed onto
valves until fully engaged.
Replace locking pin and turn 90° to lock
Sustituir el tapón de drenaje.
Retirar el conjunto de la tapa.
Quitar la manga.
Limpiar
Añadir la dosis del protector MC1+
Junta tórica
La junta de la tapa debe limpiarse e
inspeccionarse en busca de desgaste durante
las labores de mantenimiento de MagnaClean.
La práctica recomendada es sustituir la tapa
y las juntas de la válvula de drenaje con cada
mantenimiento.
"Utilizar únicamente grasa de silicona o agua
para lubricar la junta tórica.
No utilizar grasa EP ni fundente."
Girar la llave de cierre 90° y retirar.
PRECAUCIÓN: Asegúrese de que todas las
válvulas están cerradas.
Desconectar.
Retirar.
PRECAUCIÓN: Limpie e inspeccione las uniones
y lubrique las juntas únicamente con agua.
Instale el sistema de liberación rápida y el
recipiente en las válvulas.
PRECAUCIÓN: Asegúrese de presionar
firmemente el recipiente hacia las válvulas
hasta que esté completamente puesto.
Vuelva a colocar la llave de cierre y gírela 90°
para cerrarla