Replace drain plug.
Remove lid assembly.
Remove sleeve.
Clean
Dose with MC1+ Protector
O ring
The lid seal should be cleaned and checked for
wear when servicing MagnaClean. It is Best
Practice to replace the lid and drain valve seals
at each service.
"Only use Silicon grease or water to lubricate
O ring.
Do not use flux or EP grease."
Turn locking pin 90° and remove.
CAUTION: Ensure valves are off
Disconnect.
Remove.
CAUTION: Clean and inspect collets and
lubricate seals with water only.
Fit quick release trigger and canister onto
valves.
CAUTION: Ensure canister is firmly pushed onto
valves until fully engaged.
Replace locking pin and turn 90° to lock
Remettez en place le bouchon de purge.
Retirez l'ensemble couvercle.
Retirez le manchon.
Nettoyez
Dose avec MC1+ Protecteur
Joint torique
Le joint du couvercle doit être nettoyé et
vérifié quant à son usure quand l'entretien de
MagnaClean est effectué. La meilleure pratique
consiste à remplacer les joints du couvercle et
de la vanne de purge à chaque entretien.
"Utilisez seulement de la graisse siliconée ou de
l'eau pour lubrifier le joint torique.
N'utilisez pas de la graisse fondante ou EP."
Tournez l'axe de verrouillage de 90° et retirez-le.
ATTENTION : vérifiez que les vannes sont
éteintes
Débranchez.
Retirez.
ATTENTION : nettoyez et contrôlez les bagues de
serrage et lubrifiez les joints à l'eau seulement.
Installez un raccord rapide et une cartouche
sur les vannes.
ATTENTION : vérifiez que la cartouche est
poussée fermement contre les vannes jusqu'à
ce qu'elle soit totalement engagée.
Remettez en place l'axe de verrouillage et
tournez de 90° pour verrouiller
17