Replace drain plug.
Remove lid assembly.
Remove sleeve.
Clean
Dose with MC1+ Protector
O ring
The lid seal should be cleaned and checked for
wear when servicing MagnaClean. It is Best
Practice to replace the lid and drain valve seals
at each service.
"Only use Silicon grease or water to lubricate
O ring.
Do not use flux or EP grease."
Turn locking pin 90° and remove.
CAUTION: Ensure valves are off
Disconnect.
Remove.
CAUTION: Clean and inspect collets and
lubricate seals with water only.
Fit quick release trigger and canister onto
valves.
CAUTION: Ensure canister is firmly pushed onto
valves until fully engaged.
Replace locking pin and turn 90° to lock
Rimontare il tappo di scarico.
Rimuovere il coperchio completo.
Rimuovere il manicotto.
Pulire
Dosare con MC1+ Protector
O-ring
Pulire la guarnizione del coperchio e
controllarne l'usura quando si esegue la
manutenzione di MagnaClean. Le pratiche
migliori consigliano di sostituire le guarnizioni
del coperchio e delle valvole a ogni intervento di
manutenzione.
"Usare esclusivamente grasso al silicone o
acqua per lubrificare l'O-ring.
Non usare flussante o grasso EP."
Girare il fermo di 90° e rimuoverlo.
ATTENZIONE: Assicurarsi che le valvole siano
chiuse
Staccare.
Rimuovere.
ATTENZIONE: Pulire e ispezionare gli attacchi
e lubrificare le guarnizioni esclusivamente
con acqua.
Montare lo sgancio rapido e il filtro sulle valvole.
ATTENZIONE: Assicurarsi di spingere
fermamente il filtro sulle valvole finché non sia
completamente innestato.
Rimontare il fermo e girarlo di 90° per bloccare
21