The current cooler temperature is displayed on the multi-functional control unit TCU mounted on the front panel.
The setpoint temperature of the cooler can be set by pressing keys. In the event of warnings or faults, plain text
information appears on the display and is also indicated by LEDs (e.g. cooler within the setpoint range and no other
alarms - green LED, flow alarm (option) - yellow LED, temperature ±3° C [±5.4 °F] from the setpoint and humidity
alarm (option) - red LED).
The fine filter downstream of the cooler (different filter types available) provides for the necessary separation of
solids. The condition of the filter can be judged from the outside. To protect the downstream analyzers against
liquid penetration and to increase the operating reliability of the whole system, according to the selected filter type,
a suitable liquid alarm is possible or already integrated into the filter.
A group alarm or on request individual alarms including mA output for the cooler temperature at the output
terminals is available wired. Via potential-free contacts for the group alarm or the individual alarms (cooler
temperature, flow, fluid in the system), an alarm message and shutdown of the sample gas pump, if present, occurs.
Integrated sample gas pumps are available in three performance levels to choose from N3/5/9 KPE.
The flow meter FM40 arranged in the sample gas outlet with a measuring range adapted to the pump power can
be supplied for flow monitoring with a flow sensor FA-20mo. In addition, each sample gas line can be equipped
with a second sample gas outlet or bypass flow meter and flow control.
In the event of an aerosol problem, a liquid particulate filter CLF can be added downstream of the flow meter in
the sample gas outlet.
10

GOODS RECEIVING AND STORAGE

The gas conditioning unit CSS-VC.. is a fully pre-assembled unit. In addition, there are included:
• Immediately after arrival carefully remove the CSS-VC.. and any special accessories from the dispatch packaging
and check the supplied items in accordance with the delivery note and the list;
• Check the goods for shipping damage and, if necessary, inform your transport insurer immediately of any
damage.
N
ote
www.mc-techgroup.com
1 x connection cable
1 x 6-pin or 11 and 12-pin connector
1 x Instruction manual
Storage of the gas conditioning unit should be in a sheltered frost-free room!
CSS-VC-1.6 | 1.02.01