7.2
Description
Entering adjust-
ment mode step-by-
step
Adjusting the X-axis
step-by-step
Rugby 640, Accuracy Adjustment
Step
Description
7.
Mark the position of the beam.
8.
Rotate the laser 180° and allow it to self-level.
9.
Mark the opposite side of the second axis.
The Rugby is within its accuracy specification if the four marks are within
± 1.5 mm (± 1/16") from the centre.

Adjusting the Level Accuracy

In Adjustment Mode the X-axis LED indicates changes to the X-axis.
005829_001
The Y-axis LED indicates changes to the Y-axis.
005830_001
Step
Description
1.
Turn off the power.
2.
Press and hold both the Left and Right Arrow buttons.
3.
Press the Power button. The active axis is the X-axis.
The following sequence of LED behaviour occurs:
• The X-axis and the Y-axis LEDs flash alternately three times.
• The X-axis LED flashes three times, then flashes slowly until level. When the Rugby
is level, the X-axis LED is on, but does not flash.
• The Y-axis LED is off.
Step
Description
1.
Press the Left and Right Arrow buttons to increment the laser beam up and
down. Each increment is indicated by a flash of the X-axis LED and a beep
from the audio indicator.
2.
Continue to press the Left and Right Arrow buttons and monitor the spot
until the Rugby is within its specified range.
Five steps are equal to 10 arc seconds of change, or approximately
1.5 mm at 30 m (1/16" at 100').
3.
Press the Automatic/Manual Mode button to switch to the Y-axis.
The following sequence of LED behaviour occurs:
• The X-axis and the Y-axis LEDs flash alternately three times.
• The Y-axis LED flashes three times, then flashes slowly until level. When the Rugby
is level, the Y-axis LED is on, but does not flash.
• The X-axis LED is off.
X