7.2
Description
Entering adjust-
ment mode
step-by-step
Rugby 620, Accuracy Adjustment
Step
Description
7.
Mark the position of the beam.
8.
Rotate the laser 180° and allow it to self-level.
9.
Mark the opposite side of the second axis.
The Rugby is within its accuracy specification if the four marks are within
± 1.5 mm (± 1/16") from the centre.

Adjusting the Level Accuracy

In Adjustment Mode the X-axis LED indicates changes to the X-axis.
005774_001
The Y-axis LED indicates changes to the Y-axis
005775_001
Step
Description
1.
Turn off the power.
2.
Press and hold both the Up and Down Arrow buttons.
3.
Press the Power button. The active axis is the X-axis.
The following sequence of LED behaviour occurs:
• The X-axis and the Y-axis LEDs flash alternately three times.
• The X-axis LED flashes three times, then flashes slowly until level. When the Rugby
is level, the X-axis LED is on, but does not flash.
• The Y-axis LED is off.
X
Y
32