Fault Table - Audi A3 1997 Service Manual

Electrical system self-diagnosis
Hide thumbs Also See for A3 1997:
Table of Contents

Advertisement

Audi A3 1997 ➤
Electrical system Self-diagnosis - Edition 02.2002
-> Display on VAS 5051:
1 -
Content of fault memory:
- 0 faults detected
Or
- X faults detected
2 -
Fault
- Fault code
- Fault location
- Type of fault
A - Faults detected:
-
Print out information on screen or self-diagnosis log.
-
Terminate function "02 - Interrogating fault memory" by touching
◂ key.
-> Display on VAS 5051:
-
Eliminate fault(s) in line with fault table => Page
-
Select diagnosis function "02 - Interrogating fault memory" again in list and erase fault memory => Page
58
.
-
Select diagnosis function "06 - End of output" in list => Page
B - No fault detected:
-
Select diagnosis function "06 - End of output" in list => Page

3.5 - Fault table

Notes:
◆ Faults occurring in monitored sensors or components are stored in fault memory together with an indication
of the type of fault.
◆ The fault table is arranged according to the 5-digit fault codes on the left.
◆ All static and sporadic faults are stored in the fault memory:
A fault is recognised as being static if it is present for at least 2 seconds (ambient temperature sender at
least 60 seconds, coolant temperature sender only after engine has been running for at least 30 minutes).
If a fault is then no longer present, it is stored as being sporadic and "sporadic" also appears on display.
◆ After switching on ignition, all faults present are set to sporadic and only stored as being static if they are
still present after checking.
◆ Sporadic faults are erased if they do not re-occur in the course of 50 driving cycles (ignition on for at least
5 minutes, vehicle speed greater than 30 km/h).
◆ Do not immediately replace components indicated as being defective by VAS 5051, but rather: Start by
checking wiring and connectors to these components in line with current flow diagram. Also use current flow
diagram to check earth connections. This is particularly important if faults are output as being "sporadic".
◆ When eliminating an open circuit in the event of a data bus fault, always remember to twist the two data
wires of the corresponding bus system together to prevent electromagnetic interference.
50
01 - Self-diagnosis
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.