Sequence of operations
After fault memory interrogation:
-> Display on VAS 5051:
-
From list -1- select diagnosis function "05 - Erasing fault memory".
-> Display on VAS 5051:
1 -
- No display (prior to erasing)
Or
-Fault memory erased
Note:
If the following message appears in display zone -1-: "Fault memory not yet interrogated", this means that
sequence of operations has not been precisely observed. Fault memory cannot be erased until it has been
interrogated.
2 -
Note:
Is function to be implemented?
Note: Data will be erased!
-
Touch "OK" key in display -2-.
-
Terminate function "05 - Erasing fault memory" by touching ◂ key.
-
Interrogate fault memory again after performing repair work.
Note:
This erases faults stored during fault elimination e.g. on account of connectors being unplugged.

6.7 - End of output

Electrical system Self-diagnosis - Edition 02.2002
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
Audi A3 1997 ➤
171

6.6 - Erasing fault memory