Fault Table - Audi A8 1994 Service Manual

Hide thumbs Also See for A8 1994:
Table of Contents

Advertisement

A - Faults detected:
-
Print out information on screen or self-diagnosis log.
-
Terminate function "02 - Interrogate fault memory" by touching
◂ key.
-> Readout on VAS 5051:
-
Eliminate fault(s) in line with fault table => Page
-
Select diagnostic function "02 - Interrogate fault memory" again in list and erase fault memory => Page
15
.
-
Select diagnostic function "06 - End output" in list => Page
B - No fault detected:
-
Select diagnostic function "06 - End output" in list => Page

1.5 - Fault table

Notes:
◆ Faults occurring in monitored sensors or components are stored in fault memory together with an indication
of the type of fault.
◆ The fault table is arranged according to the 5-digit fault codes on the left.
◆ All static and sporadic faults are stored in the fault memory:
A fault is recognised as being static if it is present for at least 2 seconds (ambient temperature sender at
least 60 seconds, coolant temperature sender only after engine has been running for at least 30 minutes).
If a fault is then no longer present, it is stored as being sporadic and "sporadic" also appears on display.
◆ After switching on ignition, all faults present are set to sporadic and only stored as being static if they are
still present after checking.
◆ Sporadic faults are erased if they do not re-occur in the course of 50 driving cycles (ignition on for at least
5 minutes, vehicle speed greater than 30 km/h).
◆ Do not immediately replace components indicated as being defective by VAS 5051, but rather: Start by
checking wiring and connectors to these components in line with current flow diagram. Also use current flow
diagram to check earth connections. This is particularly important if faults are output as being "sporadic".
◆ When eliminating an open circuit in the event of a data bus fault, always remember to twist the two data
wires of the corresponding bus system together to prevent electromagnetic interference.
◆ On completion of repair work, fault memory is to be interrogated again and erased.
Readout on VAS 5051
00562
Oil level/temperature sender
-G266
- Open circuit/short to positive
- Short to earth
- Implausible signal
00667
Ambient temperature signal
- Open circuit/short to positive
- Short to earth
Electrical system Self-diagnosis 02.99 ➤ - Edition 05.2002
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
Possible cause of trouble
- Open circuit in wiring or short
- Oil level/oil temperature sender -
G266 defective
- Open circuit in wiring or short
5
.
17
.
17
.
Remedy
- Use current flow diagram to perform
fault-finding
=> Current Flow Diagrams, Electrical
Fault-finding and Fitting Locations bind‐
er
- Replace -G266
=> Electrical System; Repair Group 90;
Dash panel insert Dash panel insert
- Use current flow diagram to perform
fault-finding
=> Current Flow Diagrams, Electrical
Fault-finding and Fitting Locations bind‐
er
Audi A8 1994 ➤
1.4 - Interrogate fault memory
5

Advertisement