Audi A3 1997 Service Manual page 58

Electrical system self-diagnosis
Hide thumbs Also See for A3 1997:
Table of Contents

Advertisement

Audi A3 1997 ➤
Electrical system Self-diagnosis - Edition 02.2002
Display on VAS 5051
Coolant temperature gauge sender -G2
- Open circuit/short to positive
- Short to earth
Display on VAS 5051
01300
Nav. with CD drive control unit
- No communication
Display on VAS 5051 Possible cause of trouble
01302
Telematic control unit
- No communication - Open circuit in wiring or short circuit
- Incorrect control unit, i.e. no CAN capabil‐
ity
- "1" not displayed in measured value block
140 for telematics control unit =>Page
- Dash panel insert adaption not performed
correctly
Display on VAS 5051
01303
Telephone transmitter/receiver unit
- No communication
Display on VAS 5051 Possible cause of trouble
01304
Radio
- No communication - Open circuit in wiring or short circuit
- Incorrect control unit, i.e. no CAN capability - Replace control unit with one featuring
52
01 - Self-diagnosis
Possible cause of trouble
- Open circuit in wiring or short
circuit
- -G2 defective
Possible cause of trouble
- Open circuit in wiring or short circuit
- Incorrect control unit, i.e. no CAN ca‐
pability
- "1" not displayed in measured value
block 140 for navigation control unit
=>Page
70
- Dash panel insert adaption not per‐
formed correctly
70
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
Possible cause of trouble
- Open circuit in wiring or short circuit - Use current flow diagram to per‐
- Incorrect control unit, i.e. no CAN
capability
- "1" not displayed in measured value
block 140 for telephone control unit
=>Page
70
- Dash panel insert adaption not per‐
formed correctly
Fault remedy
- Use current flow diagram to per‐
form fault-finding
- Replace -G2
Fault remedy
- Use current flow diagram to perform
fault-finding
- Replace control unit with one featur‐
ing CAN capability
- Select adaption channel 62 and en‐
ter correct adaption value => Page
105
Fault remedy
- Use current flow diagram to perform fault-
finding
- Replace control unit with one featuring
CAN capability
- Select adaption channel 62 and enter
correct adaption value => Page
Fault remedy
form fault-finding
- Replace control unit with one fea‐
turing CAN capability
- Select adaption channel 62 and
enter correct adaption value =>
Page
105
Fault remedy
- Use current flow diagram to perform fault-
finding
CAN capability
105